Blog

Diode bypass failure vs. cracked cell in thermal imagery

A technician in gloves working on the back of a solar panel in the field.

Two of the most common findings in a thermal scan look almost identical to a tired set of eyes at 2x zoom: a warm patch on a module. One is a five-minute diode swap. The other means pulling the module and sending it back under warranty, if it's still covered. Telling them apart from the imagery alone saves a truck roll to confirm something you could have read off the screen.

What a bad bypass diode looks like

Every standard module has three bypass diodes, one per substring, wired to shunt current around a shaded or failed section of cells. When a diode fails short, that substring starts conducting even with no fault to bypass, and it runs warm across its full width. In thermal, this shows up as a clean rectangular block covering roughly a third of the module, bounded exactly by the substring's cell rows. The edges are straight. The heat is fairly even across the block, not concentrated in one cell.

A diode that's failed open behaves the other way around. It stops protecting its substring entirely, so if that section ever gets partially shaded, by a tree limb, a bird-drop pattern, soiling buildup, there's nowhere for the current to go but through the shaded cells themselves. That shows up as a hotspot in whichever cell happens to be shaded at scan time, and it can move module to module across a string depending on where the shade line falls that day. If you rescan the same string next quarter and the hot cell has shifted position within the substring but the module stays implicated, that's an open diode, not a cracked cell.

The giveaway for diode trouble in general: the pattern respects the substring boundary. It doesn't bleed across the dividing line into the next third of the panel.

What a cracked cell looks like

A microcrack doesn't know where the substring lines are. Cell cracks start at a pressure point, a hail strike, a mishandled install, or racking stress, and the crack line runs with the grain of the wafer's crystal structure, cutting across substring boundaries wherever the glass stress happens to travel. In thermal, that gives you an irregular shape: a jagged line, a branching pattern, sometimes just an isolated bright point at one corner of a single cell. It's small. It's confined to one cell or a sliver of one, and it crosses or ignores the substring boundary rather than filling it.

Severity matters here too. A hairline crack with good interconnect contact might barely register, a few degrees above ambient, and show up more clearly on a sunny high-irradiance day than a cloudy one. A crack that's separated the cell into isolated islands reads much hotter and sharper, because current has nowhere to flow except through the remaining contact point, concentrating heat right at the break.

Reading the pattern before you dispatch a crew

Shape and repetition are what separate the two calls in practice. A rectangular, substring-wide block that shows up the same way scan after scan points to a diode. An irregular, cell-scale mark that doesn't follow the substring lines points to a crack. If the hot area moves around within the same module between scans, suspect an open diode reacting to changing shade. If it's fixed in the same spot every time regardless of sun angle, that's consistent with a physical crack or a shorted diode holding steady.

None of this replaces an IV curve trace or a module teardown for anything you're about to warranty-claim. But it tells the crew what to bring up the row: a diode puller and spare diodes, or a module swap and the paperwork for a return. That's the difference between one stop and two.

This is exactly the kind of call a ranked findings dossier is built to make for you, sorting each hot reading by what it actually is and where it sits on the table before anyone climbs a rack. If your annual scan keeps turning up patches you're guessing at, see how Panel Soiling turns a flyover into that list before the next pass.

Worth running past your scan data the next time a finding comes back ambiguous.

Get started