RGB vs thermal imagery: what each one catches in a solar O&M inspection

RGB imagery and thermal imagery answer two different questions on a solar site, and O&M crews that only fly one of them end up missing half the findings. A visible-light pass shows you what the array looks like. A thermal pass shows you what the array is doing electrically. Neither one alone gives a crew lead a complete punch list for the next maintenance window.
What RGB catches
A high-resolution RGB flyover, shot at a ground sample distance tight enough to resolve individual panels and racking hardware, picks up everything you'd catch walking the rows yourself, just faster and from a fixed altitude. That's soiling patterns: bird streaking down a row, dust concentrated on the leading edge of a tilted table, pollen film after a spring bloom. It also catches vegetation growing up under or around a table, bent frames, cracked glass, delaminated backsheets, loose conduit, and debris that's landed on a module. And it catches the obvious stuff that never shows up on thermal at all: a missing panel, a module installed upside down, a tracker row that didn't stow correctly overnight.
RGB is good at anything you can diagnose by looking at it. It's blind to anything that only shows up as heat.
What thermal catches
Thermal imagery reads surface temperature, and on a working array temperature differences are almost always an electrical story. A cell bypassed by a failed diode runs hotter than its neighbors. A cracked cell carrying partial current heats unevenly across its surface. A string that's open or disconnected shows up as a cold patch against a warm field, since there's no current flowing through it to generate the small resistive heat a healthy string throws off. Junction boxes with a failing connection run hot. A soiling layer thick enough to shade part of a cell can trigger localized heating in the shaded area, the same hot-spot mechanism that eventually cooks a cell to failure.
None of that shows up in visible light. A string can sit dead for months with a module that looks, from the air or from the ground, identical to the one next to it. Thermal is the only pass that catches it.
Where the two disagree, and why that matters
The findings that actually change a crew's schedule come from the cases where RGB and thermal disagree on the same table. A table that reads heavily soiled in RGB but shows a normal thermal profile is a cleaning job, plain and simple. Wash it and move on. A table that looks clean in RGB but shows a hot cell or a cold string is the opposite case: no amount of washing fixes it, and it needs a tech with a multimeter, not a crew with a brush. Without both passes stacked on the same table, you can't tell which is which, and crews either clean tables that didn't need it or skip a string outage because nothing looked wrong from the ground.
This is also why a single annual flyover works better as a scheduling tool than a one-off drone pass after a storm. A paired RGB and thermal flyover run on the same cadence every year gives a crew lead a ranked list to work from: clean these tables first, send a tech to these strings, watch this row next season. That beats squinting at a heat map trying to guess what matters, and it beats paying a crew to walk every row with a handheld camera just to find the same three hot spots they found last year.
Panel Soiling runs that paired RGB and thermal pass over a site annually, at a resolution tight enough to isolate individual cells, and turns both image sets into one ranked findings dossier instead of two data dumps a crew has to reconcile on their own. If your current inspection routine still runs on handheld cameras and row-by-row walks, see how the annual flyover and findings dossier work before your next scheduling cycle. Worth a look before you lock in next season's cleaning route.