What an IV curve tracer tells you (and what it doesn't)

An IV curve tracer is the handheld tool that plots voltage against current for a string, usually a Solmetric PVA or something similar clipped onto the combiner box leads. Run the test, get a curve. Compare that curve against the manufacturer's reference curve for the module, and you can see where the string is giving up performance: a knee that sags means partial shading or soiling on a cell, a flat step usually points to a bad bypass diode, and a curve that's shifted low across the board often means a connector or a degraded module somewhere in that series string.
It's a real diagnostic, not a guess. Fill factor, Voc, Isc, all measured directly off the string instead of inferred from production data. For troubleshooting a specific underperforming combiner that an inverter report flagged, it's the right tool, and most O&M techs already carry one in the truck.
Where the curve tracer runs out of road
The limitation is coverage and labor, not accuracy. A curve tracer tests one string at a time, and someone has to physically open the combiner, land the leads, run the test, log the result, and move to the next one. On a site with a few hundred combiners that's days of a tech's time, and it only tells you about the strings you chose to test.
That's the part that matters for scheduling. Curve tracing answers "what's wrong with this string" once you already suspect something is. It doesn't tell you which of forty combiner boxes to start with, and it doesn't catch a soiling gradient building across the east side of the array where production is down a few percent but nothing has tripped an alarm yet. Soiling losses in particular tend to show up as a slow production drift long before any single string curve looks bad enough to flag, and by the time a tech is standing at that combiner with a tracer, the array has already been losing output for weeks.
Hot cells and junction box failures have the same problem. A cracked cell or a failing bypass diode runs hotter than the panels around it well before it costs enough output to show up clearly in a curve trace. You'd have to know to test that exact string to catch it early, and on a big site nobody's walking every row with a handheld thermal camera to check.
Thermal flyover as the triage step, not a replacement
A thermal flyover doesn't replace curve tracing. It tells you where to point it. Flying RGB and thermal together over the whole site gives you one pass that flags every hot cell, every string that's gone dark, and the tables where soiling is cutting into output, ranked instead of buried in a heat map someone has to squint at row by row. From there, a tech with a curve tracer goes straight to the combiners on the list instead of working through the site blind.
That's the division of labor that actually holds up: the flyover covers the whole array on a schedule and tells the crew where the losses are, the curve tracer gets the precise electrical read once a tech is standing in front of the specific string. One without the other leaves a gap, either you're testing strings at random hoping to catch something, or you've got a list of underperforming areas with no field data to confirm what's wrong once someone's on site.
If your findings list for this season is still a spreadsheet of inverter alarms and a tech's memory of which rows looked dusty last time he drove the perimeter, that's the gap Panel Soiling is built to close: an annual flyover that hands the crew a ranked dossier of which tables to clean or inspect first, so the curve tracer gets used where it earns its time.
Worth checking what a flyover would flag on your site before the next cleaning cycle gets scheduled.